Active
Standard
Most Recent
IEEE 1407:2021
IEEE Guide for Accelerated Aging Tests for 5 kV to 46 kV Extruded Electric Power Cables Using Water-Filled Tanks
Summary
Revision Standard - Active.
Provided in this guide are information and recommendations on the equipment, cable specimens, test conditions, test control methodologies, measurements, data analysis, and interpretation in performing accelerated aging tests for 5 kV to 46 kV rated cables using water-filled tanks. The accelerated aging tests may be time-to-failure tests and/or tests in which the samples are aged for fixed times followed by diagnostic testing.
This guide provides information and recommendations on the equipment, cable specimens, test conditions, test control methodologies, measurements, data analysis and interpretation in performing accelerated aging tests for 5 kV to 46 kV rated electric power cables using water-filled tanks. The accelerated aging tests may be time-to-failure tests and/or tests in which the samples are aged for fixed times followed by diagnostic testing.
The purpose of this guide is to provide users of accelerated aging tests and the resultant data with detailed insight into important test parameters and their influence, enumerate reporting requirements and recommend data analysis techniques to facilitate comparison of data within and between laboratories.
Provided in this guide are information and recommendations on the equipment, cable specimens, test conditions, test control methodologies, measurements, data analysis, and interpretation in performing accelerated aging tests for 5 kV to 46 kV rated cables using water-filled tanks. The accelerated aging tests may be time-to-failure tests and/or tests in which the samples are aged for fixed times followed by diagnostic testing.
This guide provides information and recommendations on the equipment, cable specimens, test conditions, test control methodologies, measurements, data analysis and interpretation in performing accelerated aging tests for 5 kV to 46 kV rated electric power cables using water-filled tanks. The accelerated aging tests may be time-to-failure tests and/or tests in which the samples are aged for fixed times followed by diagnostic testing.
The purpose of this guide is to provide users of accelerated aging tests and the resultant data with detailed insight into important test parameters and their influence, enumerate reporting requirements and recommend data analysis techniques to facilitate comparison of data within and between laboratories.
Notes
Active
Technical characteristics
| Publisher | Institute of Electrical and Electronics Engineers (IEEE) |
| Publication Date | 02/03/2022 |
| Edition | |
| Page Count | 53 |
| EAN | --- |
| ISBN | --- |
| Weight (in grams) | --- |
| Brochures |
|
Replaces
Previous versions
07/04/1999
Superseded
Historical