Active Standard
Most Recent

NBN ISO 19040-3:2020

Water quality — Determination of the estrogenic potential of water and waste water — Part 3: In vitro human cell-based reporter gene assay

Summary

This document specifies a method for the determination of the estrogenic potential of water and waste water by means of a reporter gene assay utilizing stably transfected human cells. This reporter gene assay is based on the activation of the human estrogen receptor alpha.
This method is applicable to:
— fresh water;
— waste water;
— aqueous extracts and leachates;
— eluates of sediments (fresh water);
— pore water;
— aqueous solutions of single substances or of chemical mixtures;
— drinking water;
— the limit of quantification (LOQ) of this method for the direct analysis of water samples is between 0,3 ng/l and 1 ng/l 17ß-estradiol equivalents (EEQ) based on the results of the international interlaboratory trial (see Annex F). The upper working range was evaluated [based on the results of the international interlaboratory trial (see Table F.3)] up to a level of 75 ng EEQ/l. Samples showing estrogenic potencies above this threshold have to be diluted for a valid quantification. Extraction and pre concentration of water samples can prove necessary if their estrogenic potential is below the given LOQ.

Technical characteristics

Publisher Bureau de Normalisation Belge (NBN)
Publication Date 09/23/2020
Page Count 50
EAN ---
ISBN ---
Weight (in grams) ---